Bypass Unit Single-Stage Form
Single-Stage Form
|
|
|
|
KBU-50B
(To place the Automatic changeover on the right side is available)
|
KBU-20A |
KBU-30A |
KBU-50B |
KBU-70B |
KBU-70G
|
Capacity (Q) |
20kg/h |
30kg/h |
50kg/h |
70kg/h |
70kg/h (See Note1) |
Inlet Pressure (P1) |
0.1 – 1.56MPa |
Outlet Pressure (P2) |
2.8 ± 0.5kPa |
Width x Height
(See Note 2) |
1,159 × 1,038mm |
1,754 × 757mm |
1,937 × 1,086mm |
Inlet Connection |
JIS 20K 15A Flanged |
JIS 20K 20A Flanged |
Outlet Connection |
Rc1 · ½
(Female screwed) |
Rc2
(Female screwed) |
Pressure of Activating Safety Valve |
7 ± 1.4kPa |
Price |
– |
– |
– |
– |
– |
|
KBU-100 |
KBU-100G |
KBU-200 |
KBU-200G |
Capacity (Q) |
100kg/h |
100kg/h (See Note1) |
200kg/h |
200kg/h (See Note1) |
Inlet Pressure (P1) |
0.1 – 1.56MPa |
Outlet Pressure (P2) |
2.8 ± 0.5kPa |
Width x Height
(See Note 2) |
2,100 × 767mm |
2,100 × 937mm |
2,330 × 944mm |
2,330 × 1,144mm |
Inlet Connection |
JIS 20K 25A Flanged |
Outlet Connection |
Rc2
(Female screwed) |
Rc4
(Female screwed) |
Pressure of Activating Safety Valve |
7 ± 1.4kPa |
Price |
– |
– |
– |
– |
Note 1: With earthquake-resistant shutoff device.
Note 2: The above width is for space between both sides flange.
The length does not include the thickness of the blind flange and the flange packing.
Height is the dimension from the center of the integrated header to the center of the drain pot.
|
|
|
Drawings |
CAD |
Performance curve |
Maunal |
Product picture |
KBU-20A |
○ |
○ |
|
|
|
KBU-30A |
○ |
○ |
|
|
|
KBU-50B |
○ |
○ |
|
|
○ |
KBU-70B |
|
○ |
|
|
|
KBU-70G |
○ |
○ |
|
|
|
KBU-100 |
○ |
○ |
|
|
|
KBU-100G |
○ |
◯ |
|
|
|
KBU-200 |
○ |
◯ |
|
|
|
KBU-200G |
○ |
◯ |
|
|
|
※各ファイルは右クリック「名前をつけて保存」からダウンロードして下さい
Bypass Unit Single-Stage Form(Switching Type Leak Detection Device)
|
Single-Stage Form
|
|
Switching Type Leak Detection Device |
|
|
| |
|
|
KBU-20AHL |
KBU-30AHL |
KBU-50BHL |
Capacity (Q) |
20kg / h |
30kg / h |
50kg / h |
Inlet Pressure (P1) |
0.1 – 1.56MPa |
Outlet Pressure (P2) |
2.8 ± 0.5kPa |
Width x Height
(See Note 1) |
1,159 × 1,030mm |
1,754 × 757mm |
Inlet Connection |
JIS 20K 15A Flanged |
JIS 20K 20A Flanged |
Outlet Connection |
Rc1 · ½
(Female screwed) |
Pressure of Activating Safety Valve |
7 ± 1.4kPa |
Price |
– |
– |
– |
Note 1: The above width is for space between both sides flange.
The length does not include the thickness of the blind flange and the flange packing.
Height is the dimension from the center of the integrated header to the center of the drain pot.
|
|
|
|
Drawings |
CAD |
Performance curve |
Maunal |
Product picture |
KBU-20AHL |
○ |
◯ |
|
|
|
KBU-30AHL |
○ |
◯ |
|
|
|
KBU-50BHL |
○ |
◯ |
|
|
|
※各ファイルは右クリック「名前をつけて保存」からダウンロードして下さい
Bypass Unit Low Pressure W Form
Low Pressure W Form
|
|
|
|
|
|
KWU-70 |
KWU-100 |
KWU-100G |
KWU-200 |
KWU-200G |
Capacity (Q) |
70kg/h |
100kg/h |
100kg/h (See Note1) |
200kg/h |
200kg/h (See Note1) |
Inlet Pressure (P1) |
0.1 – 1.56MPa |
Outlet Pressure (P2) |
2.8 ± 0.5kPa |
Width x Height (See Note 2) |
1,483×1,329mm |
1,680×1,200mm |
1,920×939mm |
2,055×1,195mm |
2,055×1,230mm |
Inlet Connection |
JIS 20K 20A Flanged |
JIS 20K 25A Flanged |
Outlet Connection |
Rc2 (Female screwed) |
Rc4 (Female screwed) |
Pressure of Activating Safety Valve |
7 ± 1.4kPa |
Price |
– |
– |
– |
– |
– |
Note) |
Note 1: With earthquake-resistant shutoff device.
Note 2: The above width is for space between both sides flange.
The length does not include the thickness of the blind flange and the flange packing.
Height is the dimension from the center of the integrated header to the center of the drain pot.
|
|
|
|
|
Drawings |
CAD |
Performance curve |
Maunal |
Product picture |
KWU-70 |
○ |
◯ |
|
|
|
KWU-100 |
○ |
◯ |
|
|
|
KWU-100G |
○ |
◯ |
|
|
|
KWU-200 |
○ |
◯ |
|
|
|
KWU-200G |
○ |
◯ |
|
|
|